E21 System Operation Introduction

E21 System Operation Introduction

1.Open the tank cover, check if there is dregs in the tank, clean up, and add No.46 anti-wear hydraulic oil to the tank to ensure the purity of the oil and avoid blocking the oil pump in the later stage.

E21 System Operation Introduction

2.Wiring, connect the pedal switch, turn on the electric cabinet switch.

E21 System Operation Introduction

(electric cabinet switch:OFF)                                                         (electric cabinet switch:ON)

3.Open the operating system switch (rotate the key, rotate the switch), and the indicator light should be on.

E21 System Operation Introduction

4.After pressing the oil pump switch, press the emergency stop button immediately. At the same time, contrast the arrow of the correct direction on the motor, and observe whether the motor leaf rotation direction is correct.

E21 System Operation Introduction

5.If it is incorrect (the motor reverses), exchange any two power lines after the main power is disconnected.If it is correct, rotate the emergency stop button to reset, and press the oil pump switch again to perform subsequent operations.

6.Rotate to single round trip mode, press the red button (stop button) for the programmings (red light on), set the XP value and YP value.

E21 System Operation Introduction

7.Press the green button (start button) to run programs (green light on), press the pedal switch to bend the plate.

E21 System Operation Introduction

8.Measure the angle of the plate bending.According to the error between the measured angle and the required angle, appropriately increase or decrease the YP value, repeat the previous step, until the measured angle is the required angle, and record the Y value and the material and thickness of the plate at the time.

In the same way, test the Y value corresponding to other required angles, and also record the related parameters.(For example, 1.2mm thick  carbon steel plate, the tested Y value of bending 90 degrees is 100.55, and the tested Y value of bending 135 degrees is 97.53)

When YP=100.6,

Bending angle>90°

E21 System Operation Introduction E21 System Operation Introduction
When YP=100.5,

Bending angle<90°

E21 System Operation Introduction E21 System Operation Introduction
When YP=100.55,

Bending angle=90°

Record the Y value and the material and thickness of the plate at the time.

E21 System Operation Introduction E21 System Operation Introduction
In the same way, test the

Y value is 97.53 when the bending angle is 135°. Record it.

E21 System Operation Introduction E21 System Operation Introduction

9.Press the P function key to enter the step program interface, select a program for programming.(Selection program 2 in this example.)

ST:Steps to be processed.

PP:Prearranged number of pieces.(Set according to actual needs.)

CP:Current number of pieces.(Generally set to 0.)

Set the number of steps and the YP and XP values of each step according to the workpiece drawings.

In this example, the number of steps is 3, the YP value of the first step is 100.55 (bending 90 degrees), the XP value is 10; the YP value of the second step is 100.55 (bending 90 degrees), the XP value is 30; the YP value of the third step is 97.53 (bending 135 degrees), the XP value is 70.

E21 System Operation Introduction

10.After the programming is complete, press the green button to run the program, press the pedal switch to bend the plate step by step.

E21 System Operation Introduction

11.After the bend is over, press the emergency stop button, turn off the oil pump, close the operating system switch (rotate the key, rotate the switch), turn off the electric cabinet switch, and the press brake is off.

 